PIE 830 Dual Channel Multifunction Diagnostic Calibrator

$1,950.00

PIE 830 Dual Channel Multifunction Diagnostic Calibrator is a dual channel multifunction diagnostic calibrator. The listed feature set includes HART communication and RTD and thermocouple functions.

Description

Overview PIE 830 Dual Channel Multifunction Diagnostic Calibrator

PIE 830 Dual Channel Multifunction Diagnostic Calibrator is a dual channel multifunction diagnostic calibrator. The listed functions include HART communication and RTD and thermocouple functions.

Features and Performance

  • Detect ā€˜hidden’ loop problems: Quickly diagnose troublesome ground faults & current leakage with patented Loop Diagnostic technology. These problems are undetectable with other instruments!
  • Check all loop parameters at once with the LoopScopeā„¢: Simultaneously displays current, voltage and resistance to let you know the condition of a live loop. Finds problems with power supplies & loops with too many loads. Patented by PIE!
  • Automatically detect 2, 3 or 4 wire RTDs: T rouble shoot sensor connections and find broken wires with patented technology. LCD indicates which of the four wires are connected to an RTD sensor
  • Swap out faulty transmitters to diagnose control issues: Easily setup the 830 as a universal isolated transmitter for temperature, frequency, millivolt or pressure. If the loop is back under control you know the transmitter was faulty. Turn on the LoopScope to simultaneously see the loop current, power supply voltage and loop loads for troubleshooting
  • Technician friendly operation Intuitive EZ-DIAL Double Click Menu makes it easier to setup than other multifunction calibrators. As easy to use as single function PIE Calibrators. Turn on the backlight to easily see the display in dark areas of the plant. Connections diagrams are indicated on the display for each function along with a labeled connector and a help chart behind the tilt stand
  • Calibrate with Confidence Accurate to ±0.02% of Reading 0.01% Full Scale
  • Measure temperature sensors, frequency pickups, loop currents, voltage levels & pressures Check the values of your process sensors. Instantly recall MAX and MIN values to see process variability
  • Guaranteed Compatibility with process inputs Compatible with the instruments you use including all brands of smart transmitters and PLCs with 14 T/C and 9 RTD types to 0.1°C and 0.1°F • Quickly set any three outputs plus automatic stepping & ramping Easily set any value with the adjustable ā€œDIALā€ plus store any three output settings for instant recall with the EZ-CHECKā„¢ switch. 2, 3, 5 & 11 steps automatically increment output in 100%, 50%, 25% or 10% of span plus continuous ramp. Set step/ramp time to 5, 6, 7, 8, 10, 15, 20, 25, 30 & 60 seconds

Why Choose This Product

This model fits broader calibration workflows because the listed functions cover more than one signal type within the same instrument.

Product Specifications

Feature Details
Accuracy 0.02% of Reading 0
Compatibility the instruments you use including all brands of smart transmitters and PLCs with 14 T/C and 9 RTD types to 0
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “PIE 830 Dual Channel Multifunction Diagnostic Calibrator”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoqueĀ dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisqueĀ vestibulum amet elit ut volutpat.